Units are not milligrams: how to tell what is in your syringe
Units on an insulin syringe measure how much liquid you draw, not how much medication is in it. The same 20 units can hold very different amounts depending on how strong your vial is.
What a unit actually is
Insulin syringes are marked in units instead of millilitres. On the standard U-100 scale, 100 units equal 1 mL, so each unit is 0.01 mL.1 A 0.5 mL syringe holds 50 units and a 0.3 mL syringe holds 30 units, on the same scale. See insulin syringe sizes.
The unit scale exists for insulin.1 When the same syringe is used for another medication, the unit marks still only tell you the volume. The FDA makes the same point: when instructions are given in units, the amount of medicine behind them depends on the concentration.2
What a milligram is
Milligrams (mg) and micrograms (mcg) measure the medication itself. One mg is 1,000 mcg. Your prescription is written in mg or mcg, because that is what matters to your body.
The link between them is concentration
Concentration is how much medication is in each millilitre of liquid, written as mg/mL. It is either printed on the vial label or set by how much water was added to the powder.
amount (mg) = units ÷ 100 × concentration (mg/mL)
Same units, different amounts
This table shows 20 units drawn from four vials of different strengths. The numbers are arithmetic examples, not doses.
| Vial strength | Units drawn | Volume | Amount |
|---|---|---|---|
| 2.5 mg/mL | 20 | 0.2 mL | 0.5 mg |
| 5 mg/mL | 20 | 0.2 mL | 1 mg |
| 10 mg/mL | 20 | 0.2 mL | 2 mg |
| 20 mg/mL | 20 | 0.2 mL | 4 mg |
The strongest vial in the table delivers eight times as much as the weakest, from the same mark on the syringe.
What the FDA has seen go wrong
In July 2024 the FDA warned about dosing errors with compounded injectable semaglutide. It had received reports of adverse events, some needing hospital care.2 The examples show how small the slip can be.
- Ten times too much from one misread line. In several reports, patients told to draw 5 units drew 50 units instead.2
- Errors in the conversion itself. One provider meant 0.25 mg, which was 5 units, but prescribed 25 units. Another prescribed 20 units instead of 2.2
- Large multiples. Most reports involved patients drawing 5 to 20 times the intended dose from a multiple-dose vial.2
The FDA lists these as contributing factors:2
- Confusion between millilitres, milligrams and units.
- Concentrations that vary. They can differ between compounders, and one compounder may offer several.
- Patients who are new to drawing medicine from a vial into a syringe.
- Syringes much larger than the volume prescribed.
Those reports were about semaglutide, but the arithmetic is the same for any vial measured with a syringe.
Other ways the numbers drift
- Copying someone else's units. A friend's "20 units" only means the same thing if their vial has the same strength as yours.
- A refill with a different strength. If the new vial is stronger and you draw the old number of units, you get more medication.
- Adding a different amount of water. If you mix a vial yourself, more water makes a weaker mix and less water makes a stronger one.
- Confusing mg with mcg. Entering 250 when you mean 0.25 is a thousand-fold difference.
These four follow from the formula above. They are our reasoning, not reported cases.
Check what is in your syringe
Enter your vial details and the units you draw. The result should match the dose on your prescription.
Units to mg
Result
- Same amount in mcg
- Volume
- Concentration
How this was worked out
This is arithmetic on the numbers you entered. It does not tell you what dose to take. Confirm with your prescriber or pharmacist.
Want to save this vial and get dose reminders? Get early access
If the result does not match your prescription, do not adjust the dose yourself. Check the numbers you entered against the vial label, then ask your pharmacist or prescriber. The FDA's advice to patients is to talk with their provider or compounder about how to measure the intended dose.2
Write down three numbers for every vial
- Your prescribed dose, in mg or mcg.
- The vial's concentration, in mg/mL.
- The units that dose works out to.
Redo the third number whenever the first or second changes. To work it out from your dose, use the reconstitution calculator or the dose to units calculator.
Questions
Are units and mg the same thing?
No. Units on an insulin syringe measure the volume of liquid. Milligrams measure the amount of medication. How many mg are in a given number of units depends on the concentration of the vial.
How many units is 1 mL?
On a U-100 insulin syringe, 100 units equal 1 mL, so 10 units is 0.1 mL.
Can I use the same units as someone else?
Only if your vial has exactly the same concentration and you have been prescribed the same dose. Otherwise the same units deliver a different amount.
What should I write down for each vial?
Three things: your prescribed dose in mg or mcg, the concentration of the vial in mg/mL, and the units that dose works out to.
How many mg is 10 units?
Ten units is 0.1 mL. Multiply 0.1 by the concentration of your vial in mg/mL. At 5 mg/mL it is 0.5 mg, and at 10 mg/mL it is 1 mg.
Why did my units change when my dose did not?
Because the concentration changed. A stronger vial needs fewer units for the same milligrams, and a weaker one needs more.
Has unit confusion caused real harm?
Yes. In 2024 the FDA reported adverse events, some needing hospital care, linked to dosing errors with compounded semaglutide, including patients who drew 50 units instead of 5.
What if I think I drew the wrong amount?
Do not inject if you are unsure. If you already have, contact your prescriber, pharmacist or local poison control service, or call your emergency number if you feel unwell.
Sources
- Pennsylvania Patient Safety Authority, newsletter, June 2025: insulin syringes are marked in units, with 1 mL equal to 100 units. patientsafety.pa.gov (opens in a new tab)
- U.S. Food and Drug Administration, "FDA alerts health care providers, compounders and patients of dosing errors associated with compounded injectable semaglutide products", 26 July 2024. fda.gov (opens in a new tab)
- Formulas and test cases: how the calculator math works.